Replaces Puritan Bennett - Covidien 10097559New Aftermarket Outright

OXYGEN SENSOR

Your price:
$123.26 each
$144.38 Savings: $21.12 (15%)
Estimated to ship by 12/24 if ordered before 6:00 PM EST
BUYING OPTIONS:
New Aftermarket
Outright Purchase
$123.26 each
Warranty: Other (See Notes)
New OEM Original
Outright Purchase
$221.34 each
Warranty: Mfr Warranty
OXYGEN SENSOR
OXYGEN SENSOR

Replaces Puritan Bennett - Covidien 10097559
OXYGEN SENSOR

New Aftermarket Outright
Your price:
$123.26 each
$144.38 Savings: $21.12 (15%)

Oxygen Sensor, 1.16 in Dia, 3 Pin Plug, 0 to 100%, White, Clear, 10 to 14 mV Signal Output, <15 sec Response, 0 to 40 Deg C, 0 to 99%

Estimated to ship by 12/24 if ordered before 6:00 PM EST
Asset Information
QtyPrice
10+ $119.56

18 Month Warranty

Product Overview

Analytical Industries Inc (Aii) % oxygen sensor are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”.

Features
  • Humidity Non-Condensing: 0 to 99% RH, Shelf Life : 6 Months, Linearity: +/-2% of Full Scale, Signal Output : 10 to 14 mV, Accuracy: +/-2% of Full Scale
Technical Specs
P/N: 10097559 Key Specs
Item
OXYGEN SENSOR
OEM
Puritan Bennett - Covidien
OEM #
10097559
Condition
New Aftermarket
Returnable
Yes
Warranty
Other (See Notes)
Accuracy
+/-2% Full Scale
Color
White, Clear
Connector Data
3 Pin Plug
Diameter
1.16 in
Humidity
0 to 99%
Linearity
2% of Full Scale
Measuring Range
0 to 100%
Number of Pins
3
Output Range
10-14mV
Power Requirements
10 to 14 mV Signal Output
Range Of Measurement
0-100%
Response Time
<15 sec
Standards
FDA, CE, ISO10993-1, 5, 10:2003E, TUV, RoHS
Temperature Rating
0 to 40 Deg C
Equivalents
Fitments

Analytical Industries Inc (Aii) % oxygen sensor are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”.

  • 10098559: Puritan Bennett - Covidien: Item Replacement
  • Puritan Bennett - Covidien
    • 980
    • 760
    • 740
    • 840
    • PB2000
  • Philips Healthcare
    • HELIX
    • TRILOGY
    • TRILOGY EVO
Product Overview

Analytical Industries Inc (Aii) % oxygen sensor are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”.

Features
  • Humidity Non-Condensing: 0 to 99% RH, Shelf Life : 6 Months, Linearity: +/-2% of Full Scale, Signal Output : 10 to 14 mV, Accuracy: +/-2% of Full Scale
Technical Specs
P/N: 10097559 Key Specs
Item
OXYGEN SENSOR
OEM
Puritan Bennett - Covidien
OEM #
10097559
Condition
New Aftermarket
Returnable
Yes
Warranty
Other (See Notes)
Accuracy
+/-2% Full Scale
Color
White, Clear
Connector Data
3 Pin Plug
Diameter
1.16 in
Humidity
0 to 99%
Linearity
2% of Full Scale
Measuring Range
0 to 100%
Number of Pins
3
Output Range
10-14mV
Power Requirements
10 to 14 mV Signal Output
Range Of Measurement
0-100%
Response Time
<15 sec
Standards
FDA, CE, ISO10993-1, 5, 10:2003E, TUV, RoHS
Temperature Rating
0 to 40 Deg C
Equivalents
Fitments

Analytical Industries Inc (Aii) % oxygen sensor are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”.

  • 10098559: Puritan Bennett - Covidien: Item Replacement
  • Puritan Bennett - Covidien
    • 980
    • 760
    • 740
    • 840
    • PB2000
  • Philips Healthcare
    • HELIX
    • TRILOGY
    • TRILOGY EVO
Product Overview

Analytical Industries Inc (Aii) % oxygen sensor are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”.

Features
  • Humidity Non-Condensing: 0 to 99% RH, Shelf Life : 6 Months, Linearity: +/-2% of Full Scale, Signal Output : 10 to 14 mV, Accuracy: +/-2% of Full Scale
Technical Specs
P/N: 10097559 Key Specs
Item
OXYGEN SENSOR
OEM
Puritan Bennett - Covidien
OEM #
10097559
Condition
New Aftermarket
Returnable
Yes
Warranty
Other (See Notes)
Accuracy
+/-2% Full Scale
Color
White, Clear
Connector Data
3 Pin Plug
Diameter
1.16 in
Humidity
0 to 99%
Linearity
2% of Full Scale
Measuring Range
0 to 100%
Number of Pins
3
Output Range
10-14mV
Power Requirements
10 to 14 mV Signal Output
Range Of Measurement
0-100%
Response Time
<15 sec
Standards
FDA, CE, ISO10993-1, 5, 10:2003E, TUV, RoHS
Temperature Rating
0 to 40 Deg C
Equivalents
Fitments

Analytical Industries Inc (Aii) % oxygen sensor are subjected to the most extensive stability test, output in air, 30″ of water column pressure test and stability at 100% oxygen. The widest range of oxygen sensors offered by Analytical Industries, Inc. are “Made in USA”.

  • 10098559: Puritan Bennett - Covidien: Item Replacement
  • Puritan Bennett - Covidien
    • 980
    • 760
    • 740
    • 840
    • PB2000
  • Philips Healthcare
    • HELIX
    • TRILOGY
    • TRILOGY EVO